MXS05DS Single-Point Ultrasonic Doppler Flow Meter
Category:
Flow Sensor Series
Qualifications and Honors
Product Description
Product Overview
The MXS05DS ultrasonic Doppler flowmeter measures flow velocity by exploiting the acoustic Doppler effect. The CPU generates a fixed‑frequency pulse signal via a PWM controller, which is transmitted into the water through a transducer. When this pulse encounters suspended particles in the water, it produces an echo signal that is received by the ultrasonic Doppler flowmeter. As these suspended particles drift with the water flow, they induce a Doppler shift—i.e., a frequency difference between the echo signal and the transmitted signal. By measuring this Doppler frequency shift, the flow velocity at the corresponding measurement point can be determined.
Product Features
• High measurement accuracy, wide measurement range; capable of measuring both weak and strong currents.
• Highly sensitive, with high resolution, and not limited by the minimum flow velocity.
• It features fast response, enabling measurement of both instantaneous and average flow velocities.
• Measurement linearity, with no calibration curve. K, C value;
• With no mechanical rotating parts, it is free from issues such as sediment clogging or entanglement by aquatic vegetation and debris, making it ideally suited for river measurements in environments characterized by high suspended sediment loads, abundant floating vegetation, and extremely harsh ice‑covered conditions.
Product Specifications
| Project | Indicator |
|
Measurement principle |
Doppler method, velocity-area method |
|
Flow measurement range |
± 0.02~ ± 5.00m/s |
|
Flow measurement accuracy |
1.0%±1cm/s |
|
Flow measurement resolution |
0.001 m/s |
|
Temperature measurement range |
-5~60℃ |
|
Temperature measurement accuracy |
±1℃ |
|
Water level range |
0–10 m |
| Water level accuracy | 0.5%F.S. |
| Operating temperature | -10℃ to 60℃ |
| Resolution | 0.001 m |
| Installation method | Bracket fixed installation |
|
Power consumption |
Less than 0.5 W |
|
Operating voltage |
DC 7.5-15V |
| Communication interface | RS485 MODBUS protocol |
|
Protection rating |
IP68 |
| Sensor size | 200*50*30mm |
Previous page