MXT03S Online Flow Monitor for Drainage Networks

Category:

Online Flow Monitor for Drainage Pipe Networks


cp Qualifications and Honors

Product Description

 Drainage Network Flow Monitor (MXT03P+MXS05D)

 

Product Package: MXT03 Host Unit + MXS05D Current Meter

 

Product Overview

The MXT03S series online flow monitor for drainage networks is a dedicated device designed specifically for monitoring flow in sewer systems. Featuring an ultra-low-power microcontroller, it operates on battery power and incorporates network communication, enabling real-time, online monitoring of water levels and flow rates without requiring external power supplies, fiber-optic links, or pole-mounted installations. It employs a single-point ultrasonic Doppler velocity sensor to measure liquid level and flow velocity upstream of the sensor, all while preserving the natural flow field.

Product Features

  In compliance with the SL651-2014 Hydrological Monitoring Data Communication Protocol – Communication Protocol

● Employs a 32-bit ultra-low-power microcontroller, with a standby current of less than 35 µA.

● Powered by a single-use, high-capacity battery; under standard operating conditions, the battery replacement cycle is no less than 2 years.

● IP68-rated design, resistant to water ingress;

Explosion-proof rating: Exia IIC T4 Ga;

● The housing is made of 316 stainless steel, offering excellent resistance to corrosion, acids, and alkalis, as well as impact resistance, making it suitable for use in sewage networks.

● Onboard temperature and humidity sensor for continuous monitoring of the enclosure’s environmental conditions;

● Onboard attitude sensor: when the device is moved illegally, it automatically sends an alert to the platform.

● High measurement accuracy, wide measurement range; capable of measuring both weak and strong currents.

● Highly sensitive, with high resolution, and not limited by the minimum flow velocity.

● Fast response time, capable of measuring both instantaneous and average flow velocity;

● Measurement linearity, with no calibration curve required. K, C value;

● Supports remote parameter configuration and monitoring, as well as remote device maintenance.

● Supports on-site configuration and maintenance via Bluetooth;

● It adopts a modular design, allowing direct replacement of the communication module without replacing the motherboard.

Technical Specifications

 

Host Parameters

 

Project

Parameter Metrics

CPU

Industrial-grade 32-bit low-power   Processor usage

FLASH

16 MB, capable of storing two years’ worth of measurement data, with automatic online upload to the database.

Wireless communication

Supports 4G/NB-IoT communication and private network communication.

Operating system

Proprietary operating system

Bluetooth communication

Supports local operations and maintenance of parameters via a mobile app.

Sensor interface

It can be externally connected to pressure sensors and Doppler flow meters to collect data on pipeline network flow velocity, flow rate, and water level.

Temperature and humidity acquisition

The motherboard features a built-in temperature and humidity sensor, enabling real-time monitoring of the internal operating environment’s temperature and humidity.

Pose Acquisition

Built-in health monitoring module (posture, status) for remote device status monitoring.

Communication antenna

External N‑type communication antenna and Bluetooth antenna enable both long-range wireless communication and short-range wireless communication.

Power supply battery

Standard configuration includes a 1080 Wh single-use lithium‑thionyl chloride battery, enabling 5-minute data acquisition and 30-minute reporting, with support for two years of maintenance-free operation.

Power consumption

Under standard configuration, the standby current consumption does not exceed 35 µA.

Operating temperature

-30~+70ºC

Storage temperature

-40~+85ºC

Operating humidity

95% (no condensation)

Installation method

Wellbore Support Installation

Protection rating

IP68

Housing material

316L stainless steel body

External dimensions

φ140x208mm

Overall machine weight

5.1kg

 

Current meter parameters

MXS05DS Doppler Current Meter MXS05DV2 Doppler Current Meter

Item Parameter Metrics Parameter Metrics
Product Specifications

Unidirectional

Two-way
Operating frequency

2M

2M
Flow velocity measurement

Flow velocity measurement employs the Doppler ultrasonic measurement principle.

Flow rate is calculated using the “velocity-area method.”

Flow velocity measurement employs the Doppler ultrasonic measurement principle.

Flow rate is calculated using the “velocity-area method.”

Liquid level measurement Adopts the principle of pressure measurement. Adopts the principle of pressure measurement.
Flow rate range

0.03 m/s ~ 5.0 m/s

±0.03 m/s ~ ±5.0 m/s

Flow velocity accuracy

0.5%±0.001 m/s 0.5%±0.001 m/s
Flow velocity resolution 0.001m/s 0.001m/s
Liquid level range 10m 10m
Level accuracy 0.3%F.S 0.3%F.S
Liquid level resolution 1mm 1mm
Operating temperature -25℃ to 55℃ -25℃ to 55℃
Installation method Bracket fixed installation Bracket fixed installation

Protection rating

IP68

IP68

Operating voltage

DC 7.5-15V

DC 7.5-15V

Power consumption

Less than 0.5 W

Less than 0.5 W
Communication interface RS485 MODBUS protocol RS485 MODBUS protocol
Sensor size 200*50*30mm 235*65*35mm

 

 