  • COD.png

COD sensor

Category:

Hydrological and Water Environment Monitoring


cp Qualifications and Honors

Product Description

Product Overview

The UV254 COD sensor employs an advanced deep‑ultraviolet UV LED cold light source, offering long service life and minimal drift. It utilizes a universally recognized, validated, high‑precision ultraviolet absorption method. No sample pretreatment is required; analysis is rapid, with no reagents or sampling equipment needed. The sensor features a self‑cleaning scraper and a 550 nm compensation light source, effectively mitigating the influence of turbidity and color on measurements. It also incorporates automatic temperature‑drift compensation, minimizing the impact of temperature variations on sensor readings. Up to seven calibration points are supported, meeting diverse application requirements.

Product Features

An internationally recognized, validated, high-precision UV absorbance method. Dual optical paths at 254 nm and 550 nm effectively eliminate the effects of turbidity and color. 0.

• The ultraviolet absorption method is used to determine organic compounds (such as COD, TOC, etc.), requiring no reagents and eliminating the need for sample digestion. It offers a wide range of parameters and can simultaneously output multiple measurements, including UVCOD, UVBOD, UVTOC, and SAC.

• Available in multiple optical path lengths—2 mm, 5 mm, and 20 mm—to meet the range and detection limit requirements of various applications. Equipped with automatic compensation for light source temperature drift, minimizing the impact of temperature on sensor measurements.

• Fast response time, with a maximum response of 10 seconds (T90).

• Employs an advanced cold-light UVLED source, offering long service life and minimal drift. Utilizes a filter‑based design combined with a PD receiver, requiring no consumables, ensuring extended lifespan and reduced drift.

• Equipped with a standard scraper, it effectively prevents biofouling.

• Supports up to 7-point calibration, suitable for various applications.

Technical Specifications

Project Parameter
Measurement method Dual-wavelength UV254 absorption method, compliant with DIN 38402 C2, DIN 38404, and HJT191 standards.
Parameter UVCOD,UVBOD,UVTOC,SAC
Light source UV LED cold light source
COD range
20 mm optical path length, 0.02–100 mg/L equivalent KHP (COD standard solution)
5 mm optical path, 0.1–500 mg/L equivalent KHP (COD standard solution)
2 mm optical path, 0.5–1000 mg/L equivalent KHP (COD standard solution)
Turbidity range 20 mm path length: 0.2–250 NTU; 5 mm path length: 1–1000 NTU; 2 mm path length: 5–2500 NTU.
Temperature range 0~100°C
Repeatability +1% FS equiv. KHP
Turbidity Compensation Automatic Turbidity Compensation
Calibration Up to seven-point calibration
Resolution 0.01 mg/L COD, 0.01 NTU turbidity
T90 10 seconds
Light source temperature drift Automatic compensation
Maximum pressure 3 Bar
Self-cleaning Standard configuration
Power consumption 750 mW under normal conditions, 2 W max (when the brush is activated)
Protection rating IP68, <10 meters
Material 316L